lessphp fatal error: failed to parse passed in variable @heading_font_weight:

Product Details

Standard prosthetic components

Κατηγορία:

ΚΟΙΝΟΠΟΙΗΣΤΕ ΑΥΤΟ ΤΟ ΠΡΟΪΟΝ

Περιγραφή

〉 All clinical indications
• Single, plural and complete edentation.
• Temporary and permanent prosthesis.
• Aesthetics.

〉 For all restorations
• Cemented, trans-screwed or removable restorations.
• Crowns, bridges and full dental arches.
• Traditional or CAD-CAM technique.

〉 A complete range of prosthetic components
• Healing abutments.
• Temporary abutments.
• Permanent machined abutments, aesthetic and retouchable.

〉 Varied prosthetic profiles
• Several gingival heights and emergence diameters.
• Emergence switching.
• Aesthetic profiles.

NATURACTIS & NATURALL+

〉 Internal hexagonal conical connection
• Sealing of the connection.
• Prosthetic stability.
• Precision of adjustments (6 positions).
• Mechanical solidity.

〉 Unique connection
• for all implant diameters.
• for the 2 implant systems.
Easy management of prosthetic parts between the laboratory and the practice.

〉 Connection proven for 9 years

〉 Emergence switching
• Connective tissue- development chamber.
• Protection of the biological seal.
• Gingival inflammation isolation remote from the crestal bone.

Cemented or screwed prosthesis? The choice is difficult since it is based on the clinical situation and particularly on your preference as a practitioner. The best technique is the one in which you are the most skilled.
ADVANTAGES AND DISADVANTAGES

〉 Advantages
• The technique on a false stump similar to the technique on natural stump.
• Occlusal surface preserved.
• Aesthetics:
– Very large choice of design and abutment material.
– Homogeneous cosmetic material (no access point for screws).

〉 Disadvantages
• Risk of sealing cement overflowing in sub-gingival position.
• More difficult to remove.
• Risk of loosening.

SELECTION CRITERIA FOR PROSTHETIC ABUTMENTS

〉 Selection criteria for prosthetic abutments
• Clinical indication: single, plural or complete edentation.
• The mouth area.
• Aesthetic requirement.
• Divergence of angle between desired prosthetic axis and implant axis.
• Estimate of the biological space.
• Occlusal and interdental areas.
• Impression technique:
– Directly on implant.
– Directly on abutment.

〉 Direct temporary abutment
• Chair-side temporisation: easy to use.
• Temporary bridges and crowns.
• Rotating and non-rotating plastic caps to support the temporary prosthesis.
• Only available for 3N+ range.

〉 Clinical indications
• Single and plural edentation.
• For all areas of the mouth.
• Ideal for aesthetics sector.

〉 Temporary trans-screwed abutment
• Made in the laboratory.
• Long term temporisation.

〉 Clinical indications
• Single, plural and complete edentation.
• For all areas of the mouth.
• Ideal for aesthetics sector.

STRAIGHT AND ANGULATED ABUTMENTS

〉 Clinical indications
• Single, plural and complete edentation.
• For all areas of the mouth.

〉 Your choice of aesthetic profiles
• Several emergence profiles are available to match the tooth to be replaced as well as possible: 4 diameters and 5 gingival heights (identification by laser marking).
• 3 angulations to correct divergence between the implant and prosthesis axes.
• Gum preservation: emergence profile of the healing abutment is identical to the definitive abutment.

〉 Safety and reliability
• Abutments delivered with an captive titanium screw: the screw is held by threading inside the prosthetic component, thereby preventing any accidental loss.
• Fastening screw with anti-unscrewing device.

DIRECT CLIP ABUTMENTS

〉 Clinical indications
• Single, plural and complete edentation.
• For all areas of the mouth.

〉 Biological space is preserved for improved aesthetic results
• Immediate and definitive placement of the abutment to preserve connective tissues.
• Impression taken directly on the abutment = POP-UP technique using DIRECT CLIP clipped transfers.

〉 Simplicity
• Several prosthetic profiles available depending on the type of tooth or teeth to be replaced (identification by laser marking).
• DIRECT CLIP kits including all the necessary parts for restoration on the chosen abutment.

PRECIOUS METAL ALLOY OVERCAST

〉 Clinical indications
• Single, plural and complete dentation.
• For all areas of the mouth.

〉 For laboratory manufacture of customised abutments using the traditional technique using overcast or chrome-cobalt abutments

〉 20° to 30° angulation correction above that of available pre-manufactured angulated abutments

CAD-CAM CUSTOMISED ABUTMENTS

〉 Clinical indications
• Single, plural and complete edentation.
• For all areas of the mouth.

〉 Aesthetic and customised prosthesis
• For your complexe cases.
• Manufacture by our expert TeknikaLab centre: customised titanium abutments using CAD/CAM.

〉 Compatible with principal competitor systems
• Customised abutments, scanbodies for digital impressions are also available for major competitor implant brands.

Prosthetic kit

〉 Content of the kit
• 1 prosthetic torque wrench 10-40 N.cm.
• 3 external hexagonal keys (short, medium, long).
• 2 external hexagonal mandrels (short, long).
• 3 internal hexagonal keys:
– For straight Tetra abutment.
– For Obi implant and O-Ring abutment (short, long).
• 2 internal hexagonal mandrels:
– For straight Tetra abutment.
– For Obi implant and O-Ring abutment (short, long).

Cemented or screwed prosthesis? The choice is difficult since it is based on the clinical situation and particularly on your preference as a practitioner. The best technique is the one for which you are the most skilled.
ADVANTAGES AND DISAVANTAGES

〉 Advantages
• Easy dismantling.
• Small prosthetic space.
• Lack of sealing cement.
• Restoration more adapted for bridges.

〉 Disadvantages
• Occlusal surface modified.
• Risk of possible unscrewing.
• Implant axis unfavourable to an ideal lingual or occlusal positioning of the screw shaft.
• Screw shaft visible.

SELECTION CRITERIA FOR PROSTHETIC ABUTMENTS

〉 Selection criteria for prosthetic abutments
• Clinical indication: single, plural or complete edentation.
• Mouth area.
• Aesthetic requirement.
• Divergence between desired prosthetic axis and implant axis.
• Estimate of biological space.
• Occlusal and interdental.
• Impression technique:
– Directly on implant.
– Directly abutments.

TETRA CONICAL ABUTMENTS

〉 Clinical indications
• Partial and complete bridges.
• Trans-screwed crown only on straight TETRA abutment.
• For all areas of the mouth.

〉 Abutments adapted to all your clinical situations
• Large selection of overdenture heights.
• 2 angulations available, 17° and 20° to correct divergence between implant and prosthetic axes.

〉 Stable, passive bridge
• Large 4.8 mm platform for stable, passive positioning of the prosthesis.
• Adapted to early or immediate loading for plural cases (All in Bar).

〉 Ergonomic design to simplify your procedures
Abutments are delivered with abutment holders to make them easy to pick up and position in relation to the desired prosthetic axis.

〉 For single teeth, biological space preserved for better aesthetic result
• Immediate and definitive placing of abutment to preserve connective tissues.
• Impression directly on abutment.

〉 Available for Naturactis – Naturall+ – Natea+ – Uneva+ ranges

PLURAL CONICAL ABUTMENTS

〉 Clinical indications
• Partial and complete bridges.
• For all areas of the mouth.

〉 Abutments adapted to all your clinical situations
• Large selection of overdenture heights.
• 2 angulations available, 17° and 20° to correct divergence between implant and prosthetic axes.
• Reduced 3,8 mm platform for narrow spaces.

〉 Ergonomic design to simplify your procedures
• Abutments are delivered with abutment holders to make them easy to pick up and position in relation to the desired prosthetic axis.

〉 Available for Naturactis – Naturall+ – Natea+ – Uneva+ ranges

CONOCTA CONICAL ABUTMENTS

〉 Clinical indications
• Single and plural gaps.
• For all areas of the mouth.

〉 Only available for Aesthetica+² range

ESTHETIBASE INTERFACES

〉 Clinical indications
• Single, plural and complete gaps.
• For all areas of the mouth.

〉 Customized and aesthetic abutments
• For your complexe cases.
• Manufactured by our TeknikaLab expert centre:
– Titanium customizable abutment (CAD/CAM).
– Zirconia abutment on aesthetic titanium base.

〉 Compatible with main competing systems
• Customized abutments, scanbodies for digital impression and Esthétibase interfaces are also available for major competing implant brands.

Prosthetic kit

〉 Content of the kit
• 1 prosthetic torque wrench 10-40 N.cm.
• 3 external hexagonal keys (short, medium, long).
• 2 external hexagonal mandrels (short, long).
• 3 internal hexagonal keys:
– For straight Tetra abutment.
– For Obi implant and O-Ring abutment (short, long).
• 2 internal hexagonal mandrels:
– For straight Tetra abutment.
– For Obi implant and O-Ring abutment (short, long).

EQUATOR ABUTMENTS

〉 Clinical indications
• Complete edentation.
• Mandible and maxilla.

〉 Ideal for:
• Restorations added to an attachment.
• Stabilisation of total restorations.

〉 Suitable for the majority of implant solutions
• Smallest attachment of the market.
• Correction from 35° to 50° of divergence between two implants thanks to the Smart Box Kit.

〉 Various stabilisation levels adapted to each patient
• 4 caps of different hardness available to adapt the retention of the prostesis.

O-RING ABUTMENTS

〉 Clinical indications
• Complete edentation.
• Mandible and maxilla.

〉 Ideal for:
• Restorations added to an attachment.
• Stabilisation of total restorations.

〉 Suitable for the majority of implant solutions
• Various heights are available to manage the soft tissue level.
• Maximum compensation of 15° for implant axis divergence.

〉 Various stabilisation levels adapted to each patient
• 3 seals of different hardness available to adapt the prosthesis retention.

LOCATOR ABUTMENTS

〉 Clinical indications
• Partial and complete bridges.
• Mandible and maxilla.

〉 Ideal for:
• Restorations added to an attachment.
• Stabilisation of total restorations.

〉 Suitable for the majority of implant solutions
• Various heights are available to manage the soft tissue level.
• Choose from 2 prosthesis kits with male sheaths depending on the divergence of implant axes.

〉 Stabilisation levels adapted to patient requirements
• Sheaths of various hardness are available for adapting the retention of the prosthesis.

Prosthetic kit

〉 Content of the kit
• 1 prosthetic torque wrench 10-40 N.cm
• 3 external allen hexagonal keys(short, medium, long)
• 2 external hexagonal mandrels (short, long)
• 3 internal allen hexagonal keys:
– for straight Tetra abutment
– for Obi implant and O-Ring abutment (short, long)
• 2 internal hexagonal mandrels:
– for straight Tetra abutment
– for Obi implant and O-Ring abutment (short, long)